Five-minute checks before you call anyone
- 1Mode — make sure the remote shows Cool (a snowflake), not Fan, Dry or Auto.
- 2Set temperature — set 24 °C. If the set point is above room temperature, the compressor will not start.
- 3Filters — slide out the mesh filters behind the front panel. If they are grey and furry, rinse them under a tap, dry them in the shade and refit. Our service schedule guide shows how.
- 4Outdoor unit — go and look. Is the fan spinning? Humming without spinning? Silent? Each points to a different fault — see outdoor unit not working.
- 5Power — check the MCB and the stabiliser. A stabiliser in time-delay or low-voltage cut-off will keep the outdoor unit off.
If those are fine and the room still is not cooling after 20 minutes, one of the causes below is likely.
The 10 causes we actually find
| Cause | What you notice | Typical fix | Starting price |
|---|---|---|---|
| Dirty filters and indoor coil | Weak airflow, musty smell | Wet service | ₹449–₹499 |
| Dirty outdoor condenser | Cools in the morning, struggles in the afternoon | Outdoor wash (part of wet service) | ₹449–₹499 |
| Failed outdoor fan capacitor | Outdoor fan not spinning or very slow; unit hums | Capacitor replacement | Quoted after inspection |
| Refrigerant leak | Cooling faded over weeks; frost on the thin pipe | Leak repair + weighed gas charge | ₹1,799 |
| Blocked drain / iced coil | Water dripping indoors, ice on pipes | Drain clearing, airflow fix | ₹499 |
| Faulty temperature sensor | Compressor cuts out early or behaves erratically | Sensor replacement | Quoted after inspection |
| PCB or inverter board fault | Error code, outdoor unit not starting | Board diagnosis and repair | ₹799 |
| Indoor blower problem | Low airflow, noise, burning smell | Motor or wheel repair | Quoted after inspection |
| Low voltage | Struggles at peak hours; stabiliser cuts in | Stabiliser or wiring check | Advice |
| Undersized AC or heat load | Runs non-stop in a top-floor or west-facing room | Right-sizing advice | Free advice |
Prices are Frostwright’s published starting rates. Every visit starts with a ₹199 inspection that is waived if you approve the repair. See the full price list. If the room is simply too big for the machine, our tonnage guide explains how to size it.
Is it really the gas?
Refrigerant circulates in a sealed loop. It is not burned or used up like petrol. If an AC is low on gas, it has a leak — and topping it up without finding the leak means you will be calling again within weeks. Read the signs of a real gas leak.
A dirty coil, a dead outdoor fan and low gas can all produce the same symptom: warm air. The only way to tell them apart is to measure — suction pressure, coil temperature and compressor current. Read more about how gas filling should be done.
When to stop troubleshooting and call
- The outdoor unit hums but the fan does not spin — a capacitor or motor is failing and the compressor can overheat.
- There is ice on the pipes or the indoor coil.
- An error code is blinking on the display — see our AC error codes guide.
- The MCB trips when the compressor starts.
- You smell burning or see scorch marks near the wiring — switch off at the MCB. See AC smells.
- Someone elderly, an infant or anyone unwell is in a room that is heating up fast — use emergency AC repair.
What to send when you book
- Brand, tonnage and approximate age of the AC
- A photo of the model sticker (indoor and outdoor unit)
- Any error code on the display
- What changed: power cut, recent service, storm, first start of the season
- Your area and a landmark
Send it on WhatsApp and you get a slot, a technician’s name and an honest arrival window. See split AC repair for what the visit includes.
Written by
Arjun Mehta · Lead diagnostic engineer
Arjun has diagnosed inverter boards, VRF communication faults and refrigerant circuits across Delhi NCR for 14 years. He leads Frostwright’s diagnostic bench and reviews every technical guide on this site.
About the teamPart of our troubleshooting guides. Technical terms such as tonnage, PCB, R32 or superheat are explained in the AC glossary.