Six signs of a genuine leak
- 1Cooling faded slowly. A leak drains the system over weeks; a sudden stop is usually electrical.
- 2Frost on the thin pipe at the outdoor unit’s service valve or on the indoor coil.
- 3Hissing or bubbling near the pipes or coils (only audible on larger leaks).
- 4Oily patches at flare nuts or coil bends — refrigerant carries compressor oil out with it.
- 5Longer running, higher bills for the same room temperature.
- 6A low-refrigerant error code on inverter ACs — see the error codes guide.
Look-alikes that are not gas
| Symptom | More likely cause | Guide |
|---|---|---|
| Warm air, outdoor fan not spinning | Fan capacitor or motor | Outdoor unit not working |
| Weak airflow, musty smell | Dirty filters and coil | Service schedule |
| Water dripping indoors | Blocked drain | Water leakage |
| Struggles only in the afternoon | Dirty condenser or undersized AC | Tonnage guide |
What a technician should measure
Suction pressure, the temperature of the suction line, and compressor current — together they show whether the system is undercharged or something else is wrong. If it is low, the next step is a nitrogen pressure test to find the leak. Only after the leak is fixed and the system is vacuumed should refrigerant go in, by weight. That is the process in our gas filling service.
Where AC leaks usually are
- Flare joints at the indoor and outdoor units — the most common, especially after shifting or a rushed installation.
- Long copper runs in high-rise flats, where pipes are bent and joined.
- Coils, where corrosion or vibration opens pinholes — see coil leak repair.
- Service valves and brazed joints on the outdoor unit.
Can low gas damage the AC?
Yes. In most AC compressors the returning cold refrigerant also cools the compressor. Run undercharged for long enough and the compressor overheats — turning a leak repair into a compressor replacement. If you see the signs above, book a leak test rather than a top-up.
Costs for every gas type are in AC gas filling cost.