First: wait five minutes
Most ACs protect the compressor with a restart delay of around three minutes after being switched on or after a power cut, and most AC stabilisers add their own time delay. A silent outdoor unit for the first few minutes is normal.
What the outdoor unit is telling you
| Symptom | Likely cause | Urgency |
|---|---|---|
| Completely silent | No power to the outdoor unit, stabiliser cut-off, communication or board fault | Check power; then book |
| Hums, fan does not spin | Failed fan capacitor or fan motor | Switch off now — the compressor can overheat |
| Fan spins, compressor does not start | Compressor capacitor, contactor, overload or inverter drive | Book a technician |
| Starts, then stops after a few minutes | Overheating, low gas, dirty condenser, or a protection trip | Book a technician |
| Error code on indoor display | The board has diagnosed something — see error codes | Note the code, then book |
Safe checks
- Mode is Cool and the set temperature is below room temperature.
- The AC’s MCB — and any separate outdoor-unit isolator — is on.
- The stabiliser display shows normal voltage and is not in delay or cut-off.
- Nothing is blocking the outdoor fan: leaves, plastic sheets, bird nests.
The common faults behind it
Capacitors are the most common failure in fixed-speed ACs, especially after a Delhi summer — cheap to replace and usually a same-visit fix (see fan motor repair). A compressor is only condemned after its start parts and windings are tested — see compressor repair & replacement. Contactors pit and stick. Inverter ACs have no start capacitor for the compressor; there the culprit is more often the outdoor board, a sensor, or the cable between indoor and outdoor units — see inverter & PCB repair.
If the unit died right after a power cut or a society generator changeover, a voltage spike may have damaged the board — our stabiliser guide explains how to prevent a repeat.
Written by
Arjun Mehta · Lead diagnostic engineer
Arjun has diagnosed inverter boards, VRF communication faults and refrigerant circuits across Delhi NCR for 14 years. He leads Frostwright’s diagnostic bench and reviews every technical guide on this site.
About the teamPart of our troubleshooting guides. Technical terms such as tonnage, PCB, R32 or superheat are explained in the AC glossary.