Why an AC makes water at all
Cooling pulls moisture out of the air. It condenses on the cold indoor coil, drips into a tray and runs outside through a drain pipe. In a humid Delhi monsoon a 1.5-ton split can produce several litres a day. A leak indoors means that water is not getting out — something is blocked, broken or tilted.
The 7 usual causes
| Cause | Clue | Fix |
|---|---|---|
| Blocked drain pipe | Steady drip from under the indoor unit; nothing coming out of the outside pipe | Flush or blow out the drain line |
| Dirty tray / algae | Musty smell, slimy water | Wet service — tray and line cleaned |
| Dirty filters → frozen coil | Ice on the coil; leak starts after the AC switches off | Clean filters; wet service |
| Drain without fall | Leak since installation, or after the unit was moved | Re-route the drain with a steady downward slope |
| Indoor unit not level | Water runs out of one end of the unit | Re-level the mounting plate |
| Torn pipe insulation | Droplets on the wall below the pipes | Re-insulate the suction line |
| Low refrigerant | Ice on the thin pipe, weak cooling | Leak repair and recharge — see gas leak signs |
What you can safely check
- 1Switch the AC off and keep water away from the electrics and the socket.
- 2Clean the filters — a choked filter is the single most common trigger.
- 3Find the drain pipe outside. If it drips while the AC runs, the line is at least partly clear; if it is dry, the blockage is inside.
- 4Look along the pipe run for sagging sections or kinks.
- 5For a window AC, check that the unit tilts slightly backwards, towards the outside.
Water outside is normal
Water dripping from the drain pipe outside while the AC is cooling is exactly what should happen. Worry only if it falls on a neighbour’s balcony — that is a routing problem, not a fault.
What it costs
Water leakage repairs — drain and insulation — start at ₹499, and a full wet service — which cleans the tray and line — is ₹499 for a split AC and ₹449 for a window AC. If the leak comes from a frozen coil caused by low refrigerant, the gas repair is quoted after a leak test. See split AC repair or window AC repair.
Written by
Arjun Mehta · Lead diagnostic engineer
Arjun has diagnosed inverter boards, VRF communication faults and refrigerant circuits across Delhi NCR for 14 years. He leads Frostwright’s diagnostic bench and reviews every technical guide on this site.