First, try a safe reset
- 1Switch the AC off with the remote.
- 2Switch it off at the MCB or wall switch and wait five minutes so the boards fully discharge.
- 3Switch on and run in Cool mode for 15 minutes.
- 4If the same code returns, note it down and book a technician. Do not open covers — capacitors inside can hold a dangerous charge.
Daikin error codes
| Code | Meaning | Usual cause |
|---|---|---|
| U4 | Indoor–outdoor communication error | Wiring, power to outdoor unit, or a board fault |
| U0 | Refrigerant shortage | Gas leak — needs leak test before charging |
| A1 | Indoor PCB fault | Indoor board failure |
| A5 | Freeze-up / high-pressure protection | Dirty coil, low airflow, or blocked filters |
| A6 | Indoor fan motor fault | Blower motor or its connection |
| C4 / C9 | Indoor coil / room temperature sensor fault | Thermistor or its connector |
| E5 / E6 | Compressor overload / lock | Overheating, low gas, or compressor start fault |
| E7 | Outdoor fan motor fault | Outdoor fan motor or obstruction |
| F3 | Discharge pipe temperature too high | Low gas or blocked condenser airflow |
| L5 | Compressor overcurrent | Inverter drive (IPM) or compressor fault |
Need a technician for a Daikin? See Daikin AC repair in Delhi NCR.
LG error codes
| Code | Meaning | Usual cause |
|---|---|---|
| CH01 | Indoor room temperature sensor error | Sensor or connector |
| CH02 | Indoor pipe temperature sensor error | Sensor or connector |
| CH05 | Indoor–outdoor communication error | Wiring, power or board fault |
| CH10 | Indoor fan motor lock | Blower motor or obstruction |
| CH21 | DC peak / inverter module fault | Inverter drive or compressor |
| CH38 | Low refrigerant / leak detected | Gas leak — needs leak test |
| CH61 | Outdoor condenser temperature too high | Blocked condenser or poor airflow |
| CH67 | Outdoor fan motor lock | Outdoor fan motor or obstruction |
More on LG faults in LG AC repair in Delhi NCR.
Samsung error codes
| Code | Meaning | Usual cause |
|---|---|---|
| E101 | Indoor–outdoor communication error | Wiring, power or board fault |
| E121 | Indoor room temperature sensor error | Sensor or connector |
| E122 | Indoor coil (evaporator) sensor error | Sensor or connector |
| E154 | Indoor fan error | Blower motor or its circuit |
| E554 | Refrigerant leak detected | Gas leak — needs leak test |
More on Samsung faults in Samsung AC repair in Delhi NCR.
Voltas, Lloyd, Blue Star and others
Many Indian-market brands use short ‘E’ or ‘F’ codes that change meaning between series — an E5 on one Voltas model is not the same as an E5 on another. Check the manual for your exact model, or send us a photo of the display and the model sticker on WhatsApp and we will tell you what it means. See Voltas AC repair or all brands we service.
What the code families usually mean
- Communication errors — the indoor and outdoor units have lost contact. Often a loose or damaged interconnecting cable, no power at the outdoor unit, or a board fault. See inverter & PCB repair.
- Sensor errors — a thermistor or its connector has failed. Usually one of the cheaper fixes.
- Fan motor errors — indoor or outdoor fan locked or not reaching speed. See outdoor unit not working.
- Refrigerant codes — the system has detected low charge, which means a leak. See signs of a gas leak and gas filling.
- Compressor / inverter drive errors — overcurrent, overheating or start failures. Needs proper diagnosis before any part is replaced. Repeated board faults after power cuts? Read the stabiliser guide.
Written by
Arjun Mehta · Lead diagnostic engineer
Arjun has diagnosed inverter boards, VRF communication faults and refrigerant circuits across Delhi NCR for 14 years. He leads Frostwright’s diagnostic bench and reviews every technical guide on this site.
About the teamPart of our troubleshooting guides. Technical terms such as tonnage, PCB, R32 or superheat are explained in the AC glossary.