The quick decision table
| Situation | Our usual advice |
|---|---|
| Capacitor, fan motor, sensor or drain fault, any age | Repair |
| Inverter board fault, AC under 8 years | Repair (board-level if possible) |
| Single leak at a flare joint | Repair and recharge |
| Repeated leaks in the coil, R22 machine | Replace |
| Compressor failed, AC over 10–12 years | Replace |
| Repair over ~50% of a comparable new AC | Replace |
| Works, but loud and power-hungry | Plan replacement before summer |
The 50% rule of thumb
If a repair costs more than about half the price of a comparable new AC — and the machine is past the middle of its life — the money usually works harder in a new, efficient unit. Below that, repair. The rule bends for nearly new machines (repair) and very old R22 machines (replace sooner).
The R22 question
R22 is being phased out, so every recharge gets more expensive and harder to source. One recharge after a fixed leak is fine; a machine that needs R22 every summer is costing you twice — in gas and in power. Prices in AC gas filling cost.
Do not forget running costs
An old fixed-speed AC can use far more electricity than a modern inverter of the same tonnage. Compare the annual kWh on the BEE star label of a replacement against your current bills — see inverter vs non-inverter.
Written by
Arjun Mehta · Lead diagnostic engineer
Arjun has diagnosed inverter boards, VRF communication faults and refrigerant circuits across Delhi NCR for 14 years. He leads Frostwright’s diagnostic bench and reviews every technical guide on this site.
About the teamPart of our buying, installing & upgrading guides. Technical terms such as tonnage, PCB, R32 or superheat are explained in the AC glossary.