Indoor unit
- 1Level mounting plate — check with a spirit level; a tilted unit leaks from one end.
- 2Core hole sloping outwards so rain and condensate cannot run back into the wall.
- 3Drain with continuous fall — no loops or uphill sections, outlet visible outside. See water leakage.
- 4Both copper lines insulated all the way, with the joints taped — bare pipes sweat and drip.
Refrigerant work
- 1Flare joints leak-tested with soap solution or a detector after tightening.
- 2Vacuum pump used before the valves are opened — not ‘purging’ with the AC’s own gas. Many manufacturers specify evacuating to 500 microns or lower, measured with a micron gauge. Ask to see the gauge.
- 3Extra gas for long runs — if the copper run is longer than the factory pre-charge covers, refrigerant is added by weight. See gas filling.
Outdoor unit
- 1Rated, rust-proofed stand, bolted down with anti-vibration pads — a loose stand is the most common source of rattles. See AC noises.
- 2Clearance for airflow as specified in the manual — never boxed in, never facing a wall a few inches away.
Electrical and handover
- 1Correct MCB and socket rating, and proper earthing — no extension boards.
- 2Cooling test — after the room settles, air leaving the indoor unit is typically 8–12 °C cooler than air going in.
- 3Paperwork — installation date, the brand’s warranty registration, and an invoice listing copper length and any extra gas.